Code Alarm ca 5152 Przewodnik Instalacji

Przeglądaj online lub pobierz Przewodnik Instalacji dla Zdalne rozruszniki Code Alarm ca 5152. Code Alarm ca 5152 Installation guide Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj

Podsumowanie treści

Strona 1 - Installation Guide

1ca5152. 2011 Audiovox Electronics Corporation. All rights reserved.PROFESSIONALSERIESAutomatic / Manual TransmissionRemote Start with Keyless EntryIn

Strona 2 - Table of Contents

10 ca5152. 2011 Audiovox Electronics Corporation. All rights reserved.6 Pin Start Harness1 PURPLE STARTER OUTPUT ( + )Locate the vehicle starter wire.

Strona 3 - BEFORE YOU BEGIN

11ca5152. 2011 Audiovox Electronics Corporation. All rights reserved. 6 PINK IGNITION 1 ( + )Locate the vehicle’s ignition wire at the ignition s

Strona 4 - 3 Pin Parking Light Harness

12 ca5152. 2011 Audiovox Electronics Corporation. All rights reserved. 4 BLACK/YELLOW PULSE DURING CRANK ( - )Locate the vehicle’s second starter

Strona 5

13ca5152. 2011 Audiovox Electronics Corporation. All rights reserved.Negative Switching LocksAll Door Lock and Unlock: Locate the lock / unlock wire a

Strona 6

14 ca5152. 2011 Audiovox Electronics Corporation. All rights reserved.Reverse Polarity Locks (5-Wire Door locks)All Door Lock and Unlock: Locate the l

Strona 7

15ca5152. 2011 Audiovox Electronics Corporation. All rights reserved.Positive Multiplexed LocksAll Door Lock and Unlock: Locate the lock / unlock wire

Strona 8

16 ca5152. 2011 Audiovox Electronics Corporation. All rights reserved.Data Bus Interface PortThis 4 pin port is used for Flashlogic Door Lock and Tran

Strona 9

17ca5152. 2011 Audiovox Electronics Corporation. All rights reserved.Manual Feature Programming - Feature Bank 2 - 51. Turn the ignition ON.2. Press a

Strona 10 - 6 Pin Start Harness

18 ca5152. 2011 Audiovox Electronics Corporation. All rights reserved.Feature Bank 1 - 3 ChirpsTransmitter Programming Refer to transmitter programmin

Strona 11 - 4 Pin Alternate Harness

19ca5152. 2011 Audiovox Electronics Corporation. All rights reserved.Feature Bank 5 - 7 Chirps4 Pin Alternate Output Control 1 LED Flash 2 LED Flash

Strona 12 - 2 Pin Door Lock Harness

2 ca5152. 2011 Audiovox Electronics Corporation. All rights reserved.Before You Begin ...

Strona 13 - Positive Locks:

20 ca5152. 2011 Audiovox Electronics Corporation. All rights reserved.Tach ProgrammingThe unit will not operate unless a tach signal is programmed or

Strona 14 - Multiplex Locks:

21ca5152. 2011 Audiovox Electronics Corporation. All rights reserved.Feature Bank 2 - Security1 - Silent Choice: Controls the normal arm/disarm chirps

Strona 15

22 ca5152. 2011 Audiovox Electronics Corporation. All rights reserved.3 - Ignition Controlled Locks: Control of door locks when the ignition is cycled

Strona 16 - Additional Ports

23ca5152. 2011 Audiovox Electronics Corporation. All rights reserved.Feature Bank 4 - Remote Start Control1 - RF Start Chirp: Turns remote start activ

Strona 17 - Set Up & Programming

24 ca5152. 2011 Audiovox Electronics Corporation. All rights reserved.7 - Crank Average / Crank Time: The length of time in which the remote startwill

Strona 18 - Transmitter Programming

25ca5152. 2011 Audiovox Electronics Corporation. All rights reserved.Feature Bank 5 - 4 Pin Alternate Output Control1 - Lt Green/Black Output : Contro

Strona 19

26 ca5152. 2011 Audiovox Electronics Corporation. All rights reserved.Transmitter Button Functions4 - Black/Yellow Output : Controls the BLACK/YELLOW

Strona 20 - Smart Tachless Mode

27ca5152. 2011 Audiovox Electronics Corporation. All rights reserved.Remote Start Shutdown DiagnosticsIf the remote start shuts down or fails to start

Strona 21 - Feature Descriptions

28 ca5152. 2011 Audiovox Electronics Corporation. All rights reserved.LT GREEN/BLACK FACTORY DISARM / PULSE BEFORE START ( - )LT BLUE FACTORY ARM

Strona 22

29ca5152. 2011 Audiovox Electronics Corporation. All rights reserved.Audiovox Electronics Corporation.Customer Service 1-800-421-3209WWW.CODE-ALARM.CO

Strona 23

3ca5152. 2011 Audiovox Electronics Corporation. All rights reserved.PROFESSIONAL INSTALLATIONSTRONGLY RECOMMENDEDInstallation Precautions:Roll down wi

Strona 24

4 ca5152. 2011 Audiovox Electronics Corporation. All rights reserved.6 Pin Start Harness11 Pin Main Harness3 Pin Parking Light Harness1GRAY/RED PARKIN

Strona 25

5ca5152. 2011 Audiovox Electronics Corporation. All rights reserved.11 Pin Main Harness4 Pin Alternate Harness2 Pin Door Lock Harness2 PURPLE DOOR TR

Strona 26 - Transmitter Button Functions

6 ca5152. 2011 Audiovox Electronics Corporation. All rights reserved.4 BLACK/WHITE ILLUMINATED ENTRY OUTPUT ( - )This wire provides a ( - ) 500mA out

Strona 27

7ca5152. 2011 Audiovox Electronics Corporation. All rights reserved.Fused +12 VoltBattery Source308787a8685BLUE/BLACK ActiveOutput Wire VATS Cont

Strona 28

8 ca5152. 2011 Audiovox Electronics Corporation. All rights reserved.9 GRAY HOOD PIN INPUT ( - )Install a Hood Pin Switch and connect to the GRAY wire

Strona 29 - WWW.CODE-ALARM.COM

9ca5152. 2011 Audiovox Electronics Corporation. All rights reserved.1 BLACK GROUNDConnect the BLACK wire to a solid chassis ground point using a ring

Komentarze do niniejszej Instrukcji

Brak uwag